AGV Motor Controller
AGV Motor Controller

AGV Motor Controller

Motor driver 3 phase, as the core drive component of AGV system, can efficiently convert electrical energy into mechanical energy to drive the wheels of AGV in travelling motion. Compared with single-phase motors, three-phase motors have higher efficiency, stronger output torque and better responsiveness, which can meet the needs of different types of agv applications in the industry.
Send Inquiry
Chat Now

AGV Motor Controller

Model:MDSM12B60G-2ROBOT

product-1172-359

product-1173-489

 

 

Overview

 

       

MDSM12B60G-2ROBOT AGV Motor Controller is a dual channel low-voltage DC servo drive designed for AGV, AMR, and automatic handling equipment. It integrates two sets of independent three-phase outputs and X5 and X6 feedback interfaces inside a 185 × 85 × 33 mm body, which can simultaneously drive the left and right motors of the differential chassis, and share one 16-60 VDC input and one set of buses; Suitable for 24 V, 36 V, and 48 V platforms, it helps reduce one set of power distribution, one bus node, and one installation position.

AGV Motor Controller's Single channel rated at 12 A, peak at 26 A, overload window of 30 s, capable of covering short-term impacts such as heavy load starting, hill driving, and obstacle crossing; Using vector control combined with closed-loop PID, the low-speed torque is smooth. Supports three modes: position, speed, and torque. The factory default speed loop is set, and it is ready within 3 seconds without any faults when powered on.

Onboard CAN (CANopen CiA DS301/DS5402, supports custom CAN) and RS485 (Modbus ASCII/RTU), can be separately connected to both old and new generations of controllers; Feedback supports ABZUVW increment (TTL single ended) and Hall, with additional WD+/WD − connected to 10K NTC, allowing motor overheating protection to be determined based on the true temperature of the winding. The equipment can monitor 18 faults, and the blockage can be comprehensively judged by overload, overcurrent, and speed deviation, and reported to the upper computer through digital output.

The upper computer software Motor Control Platform 3.0 supports Type-C and RS485 debugging; When there is no computer on site, the fault number can be read by flashing the red light twice. The factory has pre-set parameters according to the matching motor, and in most scenarios, it can be tested by wiring and powering on.

 

feature

 

1 MDSM12B60G-2ROBOTdualchannel

 

Dual channel  controller

The driver integrates two independent three-phase inverter outputs, CH1/CH2, and is equipped with two motor feedback interfaces, X5/X6. The two channels share one 16-60 VDC input and one bus. For differential driven mobile platforms, this means eliminating a set of power distribution, a bus node, and an installation position; The body size is 185 × 85 × 33 mm and can be directly embedded into the chassis control cabin.

 

2 MDSM12B60G-2ROBOTvectorcontrol

Vector control
Adopting vector control method, combined with closed-loop PID regulation to continuously correct current and torque. Current loop frequency band ≥ 1.0 kHz, step response rise time ≤ 2 ms, overshoot ≤ 8%, oscillation ≤ 2 times; The low-speed torque is smooth and the backlash is small, suitable for precise parking and low-speed cruising.

 

3 MDSM12B60G-2ROBOTthreemodes

 

Position/speed/torque control
The position loop or torque loop can be switched according to the task, used for cruise control, fixed point parking, and constant tension output. Ready within 3 seconds without any faults when powered on. The static error rate of the speed loop is ≤ 0.4%, and the speed fluctuation is ≤ 0.1% (1000 rpm, rated torque), which is more critical for inspection and handling scenarios that require stable linear speed.

 

4 MDSM12B60G-2ROBOTdualbus

CAN and RS485

Onboard 1 CAN (CANopen CiA DS301+DSP402, also supports custom CAN protocol) and 1 RS485 (Modbus ASCII and RTU dual frame format). The old platform uses 485 and the new platform uses CANopen, and the same driver can be connected. Both channels are non isolated designs, and the CAN bus needs to be externally connected with 120 Ω terminal resistors at both ends.

 

5 MDSM12B60G-2ROBOTfeedback

ABZUVW increment+Hall+NTC temperature measurement
Support ABZUVW incremental encoder (TTL single ended) and Hall feedback for closed-loop position and commutation; Set up WD+/WD − pins to connect to a 10 K NTC thermistor, and perform motor overheating protection according to the true temperature of the winding

 

6 MDSM12B60G-2ROBOTprotection

Multi protection level
Can monitor undervoltage, overvoltage, overcurrent, overload, phase loss IGBT,EEPROM, There are a total of 18 abnormalities, including overheating of the drive, motor, current deviation, speed deviation, encoder error, Hall error, communication timeout, runaway, open circuit of the brake, abnormal position, and version error. Blocked rotor is determined through a comprehensive analysis of overload, overcurrent, and speed deviation, and can be directly reported to the upper computer through digital output without the need for an external current relay.

 

7 MDSM12B60G-2ROBOTtypeCdebug

 

Type-C direct connection debugging+LED flashing code reading fault
Supports two connection methods, Type-C USB and RS485, including parameter wizard, trial operation, and monitor window (bus voltage, real-time fault position). When there is no computer on site, the red indicator light flashes twice at 330 Hz/200 Hz to report the fault number, and maintenance personnel can locate it by flashing it several times. The factory has pre-set parameters according to the matching motor, and in most cases, it can be tested by powering on.

 

 

Product detail

 

 

8 MDSM12B60G-2ROBOTproduct details

 

 

Dimension

 

product-1205-384

 

 

Specification

 

 

ltem

Parameters

Model

MDSM12B60G-2ROBOT

Limit Power Supply Range

16~60VDC

Rated Current

12Arms±2%

Maximum Current

26Arms±1%

Maximum Overload Time

30S

Overload Recovery Time

90S

Rated insulation withstand voltage

Input and output DC 1000V leakage current to the enclosure less than 3mA.

Drive Frequency

16KHz±0.1KHz

Insulation resistance of the whole machine

≥1M at 40°temperature and 95%humidity

Power Control Method

Vector control

Mean time between failures(MTBF)

≥5000 hours

FAQ

 

 

01.How to use 30 second overload? Do we need to add extra heat dissipation for continuous full load?

Single channel rated at 12 A, peak value at 26 A, peak value maintained for up to 30 seconds, followed by approximately 90 seconds recovery time; The two numbers marked in the manual are based on the premise of "no external heat dissipation". When the chassis is sealed or the ambient temperature is high, recovery will be slower. Short term climbing and heavy load starting can fully utilize the peak value, but do not select it as a long-term output current; If running continuously at full load, it is necessary to first add a radiator and recheck according to the "continuous rated 30 minutes, temperature rise not exceeding 40 K".

02.How are the two channels divided in hardware?

The left and right channels are completely independent in hardware: each has a three-phase output and motor feedback interface (left X5/right X6), which can be connected to two motors separately, one with walking and the other with steering or lifting. The shared part only has 16-60 VDC input and bus. In terms of parameters, the manual does not specify whether to save them separately by channel. In fact, after selecting the channel in Motor Control Platform 3.0, the motor parameters are matched separately according to the software interface display.

03.Can CANopen and Modbus be used simultaneously? What would happen if communication was lost?

Two physical interfaces exist simultaneously, but it is recommended to use only one protocol as the main control channel at the same time to avoid instruction overlap. The station number, baud rate, and protocol mode need to be consistent with the main station and will take effect after being saved. The communication timeout function needs to be enabled in the parameters; Once the interruption exceeds the set time, a "communication timeout" fault will be reported. The manual does not specify a specific shutdown method. It is recommended to set the timeout period long before attempting to run during debugging.

04.The encoder is TTL single ended, can it be directly connected to a differential encoder?

No. X5/X6 only provide A+B+Z+U+V+W+, without A −/B −/Z − negative terminals, belonging to TTL single ended input; If there is only differential signal on site, additional conversion is required. It is recommended to use shielded twisted pair cables, shielded layer single ended grounding, and separate the wiring from the motor power line; When the cable is too long or laid in parallel with the power line, it is easy to introduce interference, manifested as encoder errors or position jumping.

05.What will happen if NTC temperature measurement is not connected? How to connect a 10K thermistor?

WD+(X5/X6 3rd pin) is connected to the 10K NTC in the motor winding, and the other end is connected to GND. The manual directly lists "failure of the driver to detect the motor temperature interface" as one of the causes of motor overheating faults, so without temperature measurement, this protection cannot be judged based on the true temperature of the winding, leaving only overload and overcurrent as indirect protection. The NTC lead should be separated from the encoder line to avoid coupling switch noise into temperature sampling; If the NTC resistance is different after replacing the motor, the parameters need to be synchronously modified.

06.After the new machine is installed and powered on, if the motor does not turn after enabling it, in what order should it be checked?

First check the status: Ready within 3 seconds of power on when there are no faults; If the red light flashes in two segments at 330 Hz/200 Hz to report a code, first read the fault number based on the number of flashes. Check three more items: first, whether the enable signal has been truly delivered (DI is 3-12V high effective, and the input status bit can be viewed through the monitor window); The second is whether the operating mode matches the command source. When the position, speed, and torque loops are selected incorrectly, the speed command will not rotate; The third is whether the brake circuit is conductive, and reporting "brake open circuit" indicates that it is not conductive. If all three items are normal but still do not turn, then investigate the three types of causes summarized in the manual: motor feedback connection error, motor phase sequence connection error, and motor parameter setting error.

product-1159-760

product-1159-1007

product-1159-519

product-1159-735

product-1159-741

 

product-1159-722

Hot Tags: AGV motor controller, China AGV motor controller manufacturers, suppliers, factory, servo motor driver for wind turbines, servo motor driver for cutting machines, servo motor driver for value added product, servo motor driver for din deutsches institut f r normung standards, servo motor driver for logistics applications, servo motor driver for drones